What happens if a system fails?

A sensor provides incorrect readings. A control responds with a delay. Functional safety reduces precisely such risks of random malfunctions in electronic systems to an acceptable level. It detects the fault and brings the system into a controlled state before it becomes a hazard, for example by shutting it down or issuing a warning.

Functional safety is mandatory

It is at the human-machine interface in particular that it is determined whether an operator error is detected or becomes a hazard. Anyone placing vehicles or machinery on the market in Europe is liable for their safety. The EU Product Safety Regulation requires this, and national laws implement it. Anyone who neglects functional safety risks product recalls and damage to their reputation. Individuals, such as a head of development, are also personally liable.

Functional safety complements mechanical safety

Mechanical safety provides protection through design, for example via an emergency stop switch. Functional safety provides protection through the system’s behaviour in the event of a fault: a system monitors itself and reacts in a controlled manner if something goes wrong. Only when both are combined does a machine become truly safe.

How the safety level is determined

Every application requires its own classification. How serious is a potential fault? How often does it occur? How well can it be controlled? These questions determine the safety level: SIL according to IEC 61508, Performance Level (PL) according to ISO 13849 for machinery, and ASIL according to ISO 26262 for road vehicles. A brake as a whole requires a different level to a single subsystem within it.

EAO has been developing functional safety for years

Functional safety has been part of the development process at EAO since the very first intelligent components. Even with mechanical components, the principle is applied: a system must react safely in the event of a fault. Today, customers demand components with a clearly defined level of safety. As an Expert Partner for Human Machine Interfaces, EAO meets this requirement.

The PREMIUM variant of the 09 series is designed to handle emergency situations

EAO’s Series 09 Rugged CAN Keypads are available in three versions. The PREMIUM variant meets Performance Level d in accordance with EN ISO 13849 and is certified accordingly by DEKRA. In addition to ISO 13849, the development process was also aligned with ASIL B in accordance with ISO 26262. It detects faults during operation and responds to them immediately. With its robust construction, it withstands the harsh conditions of use in heavy-duty and specialised vehicles. Programmable, multi-coloured lighting clearly indicates the status at all times. Secure signal transmission to the vehicle system is carried out via the CANopen Safety protocol.

Used in road construction machinery, excavators, cranes, fire and rescue vehicles, refuse collection lorries and in agriculture, the Series 09 proves its worth every day under harsh conditions.

Clear advantages for users and manufacturers

Components with Performance Level d in accordance with ISO 13849 respond in a controlled manner even in the event of a fault, thereby reducing the risk of accidents for operators. At the same time, manufacturers’ liability risk is reduced because it is easier to demonstrate compliance with legal requirements.

Certified components also simplify the certification process for the entire machine or vehicle. This speeds up market approval and reduces costs during the development phase. In operation, higher reliability and improved diagnostics lead to fewer breakdowns. This reduces maintenance requirements and downtime.

Your point of contact for safety

EAO supports you every step of the way, from risk analysis right through to certified components.

Frequently asked questions.

What is functional safety?

Functional safety (often abbreviated to FuSa) reduces the risks posed by malfunctions in electronic systems to an acceptable level. It ensures that, in the event of a fault, a system switches to a safe state, for example by shutting down or issuing a warning.

What does EAO do in the field of functional safety?

EAO has incorporated safety into its development processes right from the start, with its very first intelligent electronic components. As an Expert Partner for Human Machine Interfaces, EAO supports customers from risk analysis right through to the supply of certified components.

Which EAO keypads meet functional safety requirements?

The PREMIUM variant of EAO’s Rugged CAN Keypads Series 09 is designed for applications requiring functional safety with Performance Level d in accordance with EN ISO 13849 and ISO 26262. The ISO 13849 version is DEKRA-certified.

Which safety level applies to which area of application?

The safety level depends on the application: for road vehicles, ASIL in accordance with ISO 26262 applies; for machinery, the Performance Level in accordance with EN ISO 13849 applies. The PREMIUM variant of the 09 Series has been developed in accordance with both standards and is certified to PL d in accordance with ISO 13849.

How does the SUPER variant of the 09 series differ from the PREMIUM variant?

Both variants are designed to meet the same standard: PL d in accordance with ISO 13849. The difference lies in the certification: only the PREMIUM variant carries the independent DEKRA certification. The SUPER variant features the same robust hardware and therefore comparable lifetime characteristics, but it does not support the CANOpen Safety protocol.

Which standards are relevant to functional safety?

The base standard is IEC 61508. Derived from this are: ISO 26262 for road vehicles and ISO 13849 for machine functions such as tippers or turntable ladders.

How are safety levels such as SIL, PL and ASIL determined?

Safety levels such as SIL, PL and ASIL are determined by three factors: How serious is the potential damage? How often does the fault occur? And how well can it be controlled or avoided? The combination of these factors results in the classification, referred to as SIL, PL or ASIL depending on the standards.

What does the ‘safety state’ of a system mean?

This is a state that protects people. The system continues to operate in a safe manner or switches to a state that minimises the risk. For example, by shutting down or reducing speed.

What is the value added by a keypad with functional safety?

A keypad with functional safety detects random faults during operation and responds to them before they become a hazard. This protects users and reduces maintenance costs and downtime for manufacturers.

What documentation is required to demonstrate functional safety?

Fault tree analyses to assess the probability of failure, as well as comprehensive documentation of all development stages. This ensures that compliance with the requirements can be demonstrated.

Is the PREMIUM variant of the 09 Series compatible with existing CAN systems?

Yes. Secure data transmission takes place via CANopen Safety, a safety layer based on the widely used CANopen protocol. This facilitates the integration of the 09 series into existing CAN architectures.

Can standard HMIS without safety features be used in safety-critical applications?

Yes, this is possible. Service life specifications and relevant data on the keypad’s robustness and reliability are also available for the SUPER variant.

Sales Meeting Participants 2025 (SKO)

Contact us.

Globally active – with local points of contact.

Contact: Do you have questions about EAO, our products and our solutions? We will be happy to help – after all, we know that working closely with our customers alongside excellent service are key to our success.

Contact

EAO Corporation

One Parrott Drive
Shelton, CT 06484

+1 203 951 4600sales.eus@eao.com

Find your contact.

Remove all filters

Please select a country or company type to find the right contact person for you.