The switches comply with the “Standards for low-voltage switching devices” DIN EN IEC UL 60947-5-1
Thermal current Ith:
Max. current as per EN IEC 60947-5-1 10 A
Caractéristiques mécaniques
Terminal:
Double plug-in terminal, 6.3 x 0.8 mm
Contact material:
Silver
Switching system:
Slow-make switching element
Switching system:
The double-break, slow-make switching element is equipped with one or two independent contact systems, acting as normally open or normally closed contact. The normally closed contact has forced opening.
Slow-make contacts with forced action are ideal for high switch ratings.
Operating force:
1 Normally closed approx. 2 N, 1 Normally open approx. 3 N
Wire cross section:
Double plug-in terminal 2 x 6.3 mm x 0.8 mm
Weight:
0.024 kg
Conditions environnementales
IP Protection:
IP00
Operating temperature:
– 40 °C … + 55 °C
Storage temperature:
– 40 °C … + 85 °C
Shock resistance:
(single impacts, semi-sinusoidal) 300 m/s², pulse width 18 ms, as per DIN EN 60068-2-27
Vibration resistance:
(sinusförmig) 100 m/s² bei 10 Hz…500 Hz, nach DIN EN 60068-2-6, Erhöhtes Breitbandrauschen nach DIN EN 61373, Klasse 1B
Climate resistance:
Relative humidity 10 %rh ... 95 %rh (non-condensing) original packaging according to DIN EN IEC 60721-3-1 Class 1C1
Certificats
Approbations:
CB (IEC 60947-5-1), cULus, DNV, VDE
Conformities:
CE, CCC, UKCA
REACH:
REACH compliant
RoHS:
RoHS compliant
Autres
Short Description:
Switching element - New Version, Slow-make switching element, 500 V @ 10 A, Silver, 1 NC / 1 FS, Double plug-in terminal, 6.3 x 0.8 mm
Hints:
When using the switching element, the application guidelines must be observed.
For the third switching element the terminal marking insert is to be ordered separately
Operating temperature: Other temperatures on request
A suitable enclosure is required for applications with increased protection requirements. In North America, the product must be installed in an enclosure in accordance with UL 50E Type 2 or higher.
Special requirements:
Special requirements for positive-opening auxiliary current switches
Positive opening travel
Emergency stop 12.5 mm
Minimum force
Emergency stop 50 N (actuating force at
which is safely switched)
Max. travel
Emergency stop 12.5 mm
Wiring diagrams:
A = mounted, not actuated B = mounted, actuated C = not mounted, not actuated