The switches comply with the “Standards for low-voltage switching devices” EN IEC 60947-5-1
Thermal current Ith:
10 A Max. permissible current for continuous operation and ambient temperatures not exceeding the specified max. values.
Caractéristiques mécaniques
Terminal:
Plug-in terminal, 6.3 x 0.8 mm
Contact material:
Silver
Switching system:
Slow-make switching element
Switching system:
The double-break, slow-make switching element is equipped with one or two independent contact systems, acting as normally open or normally closed contact. The normally closed contact has forced opening.
Slow-make contacts with forced action are ideal for high switch ratings.
Operating force:
1 Normally closed approx. 2 N, 1 Normally open approx. 3 N
Wire cross section:
Plug-in terminal 1 x 6.3 mm x 0.8 mm or 2 x 2.8 mm x 0.8 mm
For switches with plug-in terminals it is necessary to provide insulation sleeves and to maintain a spacing of 65 mm between rows (mounting cut-outs).
Weight:
0.018 kg
Conditions environnementales
IP Protection:
IP00
Operating temperature:
– 40 °C … + 55 °C
Storage temperature:
– 40 °C … + 85 °C
Shock resistance:
300 m/s², pulse width 11 ms, 3-axis, (single impacts, semi-sinusoidal as per DIN EN 60068-2-27)
Vibration resistance:
100 m/s² at 10 Hz … 500 Hz, amplitude 0.75 mm, (sinusoidal according to DIN EN 60068-2-6)
Climate resistance:
Relative humidity, max. 95%, non-condensing
Certificats
Approbations:
CB (IEC 60947-5-1), cULus, DNV, EAC, NFF, VDE
Conformities:
CE, CCC, UKCA
REACH:
REACH compliant
RoHS:
RoHS compliant
Autres
Short Description:
Switching element - Not recommended for new design, Slow-make switching element, 500 V AC @ 6 A, Silver, 1 NO, Plug-in terminal, 6.3 x 0.8 mm
Hints:
When using the switching element, the application guidelines must be observed.
For the third switching element the terminal marking insert is to be ordered separately
Operating temperature: Other temperatures on request
Special requirements:
Special requirements for positive-opening auxiliary current switches
Positive opening travel
Emergency stop 12.5 mm
Minimum force
Emergency stop 50 N (actuating force at
which is safely switched)
Max. travel
Emergency stop 12.5 mm
Wiring diagrams:
Dimension drawings:
A = Screw terminal B = Push-in terminal (PIT) C = Plug-in terminal 6.3 mm x 0.8 mm D = Double plug-in terminal 6.3 mm x 0.8 mm